Want to create interactive content? It’s easy in Genially!

Get started free

JEOPARDY - ACCT ICE EDITION

Building With Wood, LLC

Created on February 25, 2026

Start designing with a free template

Discover more than 1500 professional designs like these:

Essential Business Proposal

Project Roadmap Timeline

Step-by-Step Timeline: How to Develop an Idea

Artificial Intelligence History Timeline

Momentum: Onboarding Escape Game

Momentum: Manager Guide

Wizardry Letter

Transcript

ACCT ICE EDITION

DOUBLE JEOPARDY

Weights and Measurments

JOBSITE AND CONSTRUCTION

SPECIALTY HARDWARE

PERSONAL PROTECTION EQUIPMENT

WHAT'S WRONG WITH THIS PICTURE

BLUEPRINTS AND TECHNICAL DRAWINGS

WHAT'S WRONG WITH THIS PICTURE

BLUEPRINTS & TECHNICAL DRAWINGS

SPECIALTY HARDWARE

WEIGHTS & MEASURES

JOBSITE & CONSTRUCTION

PPE

DOUBLE JEOPARDY

DOUBLE JEOPARDY

HAUL SYSTEMS

TECHNICAL DRAWINGS

QUICK MATHS

TRADE SKILLS NOT TYPICALLY USED

REGULATORY JARGON

GRAB BAG

TECHNICAL DRAWINGS

REGULATORY JARGON

TRADE SKILLS NOT TYPICALLY USED

GRAB BAG

HAUL SYSTEMS

QUICK MATHS

$400

$400

$400

$400

$400

$400

$800

$800

$800

$800

$800

$800

$1200

$1200

$1200

$1200

$1200

$1200

$1600

$1600

$1600

$1600

$1600

$1600

$2000

$2000

$2000

$2000

$2000

$2000

FINAL JEOPARDY

FINAL JEOPARDY

MAKE YOUR WAGER

CATEGORY: ESSENTIAL NON-WORK SKILLS

WHICH CARD SHOULD YOU PLAY TO WIN THIS TRICK? (❤️ IS TRUMP)

REVEAL

TRICK

HAND

$1600

Name two out of three Pieces of documentation which shall be maintained by the owner/operator Under ASTM standards

1. Initial acceptance inspection report2. Acceptance inspection report/s for all major course modifications3. Written policies, procedures and operational practices

ANSWER

Select the appropriate choice from the bottom row to complete the sequence in the top row.

ANSWER

If there are 133 wires in 3/8” 7x19 GAC and the breaking strength is listed by the manufacturer as 14,400 lbs. and one strand of wires is completely broken what is the estimated breaking strength of the wire rope in service? (CALCULATOR ALLOWED, ANSWERS ±10LBS ALLOWED)

ANSWER

12,342 Lbs.

Define Tensile Strength

The force applied in-line to pull a component to the point it breaks

ANSWER

WHY DID THIS FAIL?

ANSWER

OVERGROWTH

3/8” converted to a decimal fraction is:

ANSWER

0.375

$800

If wheel A turns Clockwise what direction do wheels B and C turn?

B = COUNTER-CLOCKWISE C=CLOCKWISE

ANSWER

If a bolt has a safe working load of 20,000 lbs when the force is applied in-line (100%). What would be the reduced working load limit when the force is applied at a 90 degree angle?

ANSWER

5,000 lbs (25%)

A supplemental drawing used with a conventional working drawing that gives a complete and more exact description of the items in use is called the:

ANSWER

Detail Drawing

$1200

Please identify the bolt size specified for attaching the D Plate Anchor Connector:

ANSWER

1 /2” A 325

3/8” converted to a decimal fraction is:

ANSWER

0.375

$2000

What is the Mechanical Advantage of this System?

ANSWER

5:1

Wood poles used as critical element support structures shall comply with prevailing editions:

American National Standard for Wood Products (ANSI 05.1 and 05.2)

ANSWER

WHY DID THIS FAIL?

ANSWER

LUMBER CRACK DUE TO TREE GROWTH

A site plan is a plan view (as viewed from above) that shows

Property boundaries, buildings, roads, and elevation marks.

ANSWER

REVEAL

The ASTM collection of standards for amusement rides is frequently referred to as What

ANSWER

F-24 Standards

Which is correct?

ANSWER

#1

$400

Identify the bead size of the welds required for proper fabrication

ANSWER

1/4"

TRUE OR FALSE: Climbing to inspect equipment and components shall be done when safe and accessible to an inspector.

ANSWER

TRUE

If a bolt has a safe working load of 20,000 lbs when the force is applied in-line (100%). What would be the reduced working load limit when the force is applied at a 90 degree angle?

ANSWER

5,000 lbs (25%)

$400

Which type of Fire Extinguisher should never be used on an oil fire?

ANSWER

WATER

On completed construction projects, who is normally responsible for ensuring that the installation complies with the provided drawings and/or building codes during a commission inspection?

ANSWER

The commissioning inspector

$2000

If 5/16” 7x7 wire rope has a minimum breaking strength of 9,200 lbs. and two wires are broken, what is the new minimum breaking strength for the wire rope (round to the nearest whole number)?

ANSWER

8824 lbs.

WHAT GOES IN THE YELLOW BOX?

ANSWER

45°

Metric Fasteners have a number on the head such as 8.8 or 12.9. This mark?

Identifies the strength of the fastener

ANSWER

$2000

WHAT IS THE ASTM Standard Practice for Design of Amusement Rides and Devices?

ANSWER

2291

A site plan is a plan view (as viewed from above) that shows

Property boundaries, buildings, roads, and elevation marks.

ANSWER

$800

You have been hired to conduct a third-party inspection on a newly constructed element. What type of inspection are you conducting?

ANSWER

ACCEPTANCE

REVEAL

DEFINE FALL FACTOR

ANSWER

$800

IN MANUFACTUING, WHAT IS THE NAME OF THE PROCESS BY WHICH A LIQUID MATERIAL is introduced into a mold and allowed to solidify BEFORE then pushed out once solid as a completed part?

ANSWER

CASTING

REVEAL

DEFINE FALL FACTOR

ANSWER

$1600

Continuous grade lines that show the height above or below a given reference point DESCRIBE WHAT?

ANSWER

SITE CONTOURS

WHY DID THIS FAIL?

ANSWER

CRACK

$1200

It is the responsibility of the _____________ to ensure that you as an inspector are qualified and if required registered with a jurisdictional authority to inspect a structure deemed an Amusement Ride prior to inspecting a ride in that region.

YOU, THE INSPECTION BODY, OR YOUR EMPLOYER

ANSWER

If blueprints show fastener attachments, why can’t the contractor have just used the cheapest fasteners they could find?

"The written specifications may demand a specific grade or coated fastener as well as size tomeet a standard, local building code and or corrosion resistance."

ANSWER

Which is correct?

ANSWER

#1

REVEAL

If the breaking strength of a forged bolt is 10,000 lbs. and we want to proof test the bolt to 20% of the breaking strength, how many US tons of force would need to be applied?

ANSWER

Components that penetrate the pole shall be at least how many inches from the top of the poles unless the pole is properly capped or otherwise treated

ANSWER

12 Inches

$1200

You have a piece of wood that measures 2’ long x 2” wide. You need to rip that piece into smaller parts 1⁄2” wide by 2’ long. Knowing that you will lose some of the wood as you cut, how many 1⁄2” strips can you get out of the 2’ x 2” piece?

ANSWER

$2000

WHAT SHOULD YOU REFERENCE FOR A SMALLER VIEW OF THE DETAIL SHOWN HERE?

ANSWER

SHEET 4

$1200

WHAT IS THE NAME OF THIS DEVICE?

TENSION METER

ANSWER

WHAT MEASUREMENT IS D?

ANSWER

1-7/8"

Components that penetrate the pole shall be at least how many inches from the top of the poles unless the pole is properly capped or otherwise treated

ANSWER

12 Inches

Wood poles used as critical element support structures shall comply with prevailing editions:

American National Standard for Wood Products (ANSI 05.1 and 05.2)

ANSWER

$1200

To lift the 150 lb. weight illustrated, you need to pull down with a force of about _____ pounds.

ANSWER

75 (2:1)

WHY DID THIS FAIL?

ANSWER

OVERGROWTH

$2000

In the circuit shown, how many switches need to be closed to light up at least one bulb?

ANSWER

TWO

SAE is an identifying mark of a fastener that was made to what standard?

Society of Automotive Engineers

ANSWER

WHAT GOES IN THE YELLOW BOX?

ANSWER

45°

Name two of the three requirements for verifying life safety system integrity, as specified in the ANSI/ACCT Standards?

1. Presence of a redundant system, 2. system meets or exceeds a verifiable life safety standard, 3. system is proof tested or engineered.

ANSWER

WHY DID THIS FAIL?

ANSWER

LUMBER CRACK DUE TO TREE GROWTH

While ACCT standards specify minimum standards for participant equipment; what standard shall be used for employees performing professional inspections on a course or structure?

The standard required by law for employees working at height in the country, state,providences or otherwise having legal jurisdiction.

ANSWER

Select the appropriate choice from the bottom row to complete the sequence in the top row.

ANSWER

Newly Installed Critical Guy anchors need to be properly designed and stamped by a licensed engineer or proof tested to a minimum of____ the expected load.

ANSWER

2x

Define Tensile Strength

The force applied in-line to pull a component to the point it breaks

ANSWER

$800

IS THE LIGHT ON OR OFF?

ANSWER

OFF

On completed construction projects, who is normally responsible for ensuring that the installation complies with the provided drawings and/or building codes during a commission inspection?

ANSWER

The commissioning inspector

$400

A 10-foot long class IV wood pole can hold a uniform load of 420 pounds per ft. what total load can the beam support?

ANSWER

4,200 lbs.

SAE is an identifying mark of a fastener that was made to what standard?

Society of Automotive Engineers

ANSWER

NFPA is an acronym for...

The National Fire Protection Association

ANSWER

While ACCT standards specify minimum standards for participant equipment; what standard shall be used for employees performing professional inspections on a course or structure?

The standard required by law for employees working at height in the country, state,providences or otherwise having legal jurisdiction.

ANSWER

REVEAL

The ASTM collection of standards for amusement rides is frequently referred to as What

ANSWER

F-24 Standards

WHAT IS THIS CALLED?

ANSWER

BIRDCAGE

$400

True or False: An installation can vary from the ACCT or ASTM standards as long as it has been stamped by a structural engineer and testing to the ASTM standards of those provided by the engineer have been completed and are properly documented

ANSWER

TRUE

All new installations shall comply with what version of the ANSI/ACCT Standard

The current Published Edition at the time of installation

ANSWER

$1600

Which of the following is not a typical part of an electric circuit A. Power source B. Conductor C. Load D. Fillet

ANSWER

D. Fillet

$400

To lift the 100 lb. weight illustrated below, you need to pull with a force of about _____ pounds.

ANSWER

100 (1:1)

$1600

On a zip line using 1⁄2” sized wire rope with an ultimate breaking strength of 26,600 lbs. which of the following combination of dead and live loads would be acceptable and pass inspection.

ANSWER

4,160 lbs.

$800

To lift the 100 lb. weight, you need to pull up with a force of about _____ lbs.

ANSWER

50 (2:1)

If there are 133 wires in 3/8” 7x19 GAC and the breaking strength is listed by the manufacturer as 14,400 lbs. and one strand of wires is completely broken what is the estimated breaking strength of the wire rope in service? (CALCULATOR ALLOWED, ANSWERS ±10LBS ALLOWED)

ANSWER

12,342 Lbs.

Name two of the three requirements for verifying life safety system integrity, as specified in the ANSI/ACCT Standards?

1. Presence of a redundant system, 2. system meets or exceeds a verifiable life safety standard, 3. system is proof tested or engineered.

ANSWER

What is the best tool for assessing that a 10’ vertically oriented wood pole is straight up and down?

ANSWER

Plumb Bob

$1600

To lift the 200 lb. weight illustrated, you need to pull down with an approximate force of about _____ pounds.

ANSWER

67 (3:1)

WHY DID THIS FAIL?

ANSWER

CRACK

TRUE OR FALSE: Climbing to inspect equipment and components shall be done when safe and accessible to an inspector.

ANSWER

TRUE

A supplemental drawing used with a conventional working drawing that gives a complete and more exact description of the items in use is called the:

ANSWER

Detail Drawing

Name 2 reasons a Carabiner may fail inspection

1. Corrosion or excessive wear2. Improperly operating gate and/or locking mechanism3. Minimum strength requirement marked on the component is too low

ANSWER

$2000

Draw it: in a hydraulic/pneumatic assembly diagram, a hydraulic cylinder

ANSWER

Metric Fasteners have a number on the head such as 8.8 or 12.9. This mark?

Identifies the strength of the fastener

ANSWER

WHAT IS THIS CALLED?

ANSWER

BIRDCAGE

NFPA is an acronym for...

The National Fire Protection Association

ANSWER

$400

what is the technical term for a cutaway view of an object or structure?

ANSWER

Sectional Drawing

All new installations shall comply with what version of the ANSI/ACCT Standard

The current Published Edition at the time of installation

ANSWER

If blueprints show fastener attachments, why can’t the contractor have just used the cheapest fasteners they could find?

"The written specifications may demand a specific grade or coated fastener as well as size tomeet a standard, local building code and or corrosion resistance."

ANSWER

REVEAL

USING YOUR HANDS, SHOW A LAP JOINT IN WELDING

ANSWER

WHAT MEASUREMENT IS D?

ANSWER

1-7/8"

Name 2 reasons a Carabiner may fail inspection

1. Corrosion or excessive wear2. Improperly operating gate and/or locking mechanism3. Minimum strength requirement marked on the component is too low

ANSWER

What is the best tool for assessing that a 10’ vertically oriented wood pole is straight up and down?

ANSWER

Plumb Bob

$1600

In a first class lever, how could you increase the amount of mechanical advantage?

Move the load closer to the fulcrum / the effort further from the fulcrum

ANSWER

Newly Installed Critical Guy anchors need to be properly designed and stamped by a licensed engineer or proof tested to a minimum of____ the expected load.

ANSWER

2x