Improvement Measures Activity

NOTE: Consider only the conditions that trigger an improvement measure, and ignore the SAP difference that is required for it to appear.

IMPROVEMENT MEASURES

Navigate by using the page numbers below

1a. Loft insulation scenario

At an inspection of a 1930s semi-detached house, you measure 100mm loft insulation.

Is the software likley to trigger a recommendation to increase loft insulation?

1. Loft insulation thickness

No

Yes

When loft insulation is included as an improvment measure on the EPC, what thickness does it recommend?

Reveal

IMPROVEMENT MEASURES

2. Doors

You carry out an energy assessment on a first-floor flat. It has a single door that opens onto a communal corridor, and this door is not insulated. Which improvement measure is most likely to appear on the EPC?

Replacement door with a U-value of 1.4 W/m²K.

No improvement measure will appear for an insulated door.

Add draughtproofing to the door.

IMPROVEMENT MEASURES

3. Draughtproofing

A customer is unhappy to see draughtproofing recommended on their EPC, noting that over half their windows and doors are already draughtproofed. They ask: what minimum percentage of draughtproofing prevents this measure from appearing on the EPC?

75%

85%

100%

IMPROVEMENT MEASURES

4. Cylinder insulation

A customer queries their EPC and says: “I don’t understand why you’ve recommended improving my hot water cylinder insulation. The cylinder already has factory-fitted insulation, and it’s 25 mm thick. Surely that’s already insulated enough?”.

Drag and drop here

Which of the following sentences do you think correctly apply to this scenario:

(drag and drop into the box above):

RdSAP treats 25mm factory applied insulation as equivalent to 80mm loose jacket.

RdSAP treats 25mm factory applied insulation as equivalent to 50mm loose jacket.

25mm factory applied insulation is sufficient, I'm sorry, there has been an error.

Cylinders with 25mm factory applied insulation or less are eligible for improvement.