Want to make interactive content? It’s easy in Genially!

Transcript

ECITB Level 3 Pipefitting RQF

Start

Ewan Casserly Technical Discussion

Index

Home

IPS01

IPS02

IPS03

IPS04

IPS05

IPS07

IPS08

IPS10

IPS11

IPS01

Home

L3B0111-K30 Which of these is not true about toolbox talks? L3B0113-B3 An informal and unstructured communication channel that cuts across formal channels of communication is called: L3B0104-K30 Which of these is a consequence of not following procedures? L3B0120-K28 What is NOT true of the relationship between change and stress? L3A0126-K20 Which of these systems is designed to alert managers to uncontrolled risks?

PF0207-K1 Where would you find information on which type of grease to use when assembling a valve stem?PF0237-K1 You are working on top of a boiler and need to install a valve on top of the unit, where would you find information about the safety whilst conducting this task? select two answers L30250-K8 What procedure is used to inform all work party members of the planned activity? L30219-K8 Why is it important to complete documentation correctly? L30246-K10 Handover information forms part of which file? L30208-K1 At what stage should equipment compatibility checks take place?

IPS02

Home

PF0326-K6 Which pattern development methods is shown in the picture? PF0308-K2 How is the minimum bend radius of a pipe usually approximately calculated? PF0316-K3 How should the surface of a GRP pipe be prepared for marking out? PF0330-K3 When preparing for marking out a stainless steel pipe template, which of the following would be the best marking medium? PF0302-K4 A template is to be positioned on a pipe but the centre finder is NOT available, what else can be used to accurately mark the centre line?

IPS03

Home

PF0337-K4 Why is there usually a distance between two hydraulically formed bends in a pipe section? PF0318-K4 Use the diagram to help calculate the travel between the angles of an offset if the advance is 12 inches and the set is 6 inches. PF0315-K6 The given image shows a pipe template, what sort of pipe shape will result when the form is created?

IPS03

Home

PF0404-K2 Which tool is best suited for removing burrs from the internal edge of a cut 25mm diameter thin wall copper tube? PF0420-K2 Complete the sentence - Softer materials should be sawn using a blade with ______ teeth than for harder materias. PF0418-K4 The machined edge of a piece of carbon steel has turned blue due to over heating, what effect does this have on the material characteristics? PF0410-K4 A section of GRP pipe has white markings over its outside surface, what would this defect indicate?

IPS04

Home

PF0530-K2 When the stresses on the outside radius overcomes the ability of the tube cross section to support it - What is this describing? PF0507-K7 You are sizing up material for a job, what would be the approximate length needed to for a 90 degrees bend length with a centre line radius of 200mm?

IPS05

Home

PF0703-K1 Which type of gasket is recommended for sealing high pressure steam flange connections and components? PF0714-K2 The picture shows a type of sealing joint, what type of flanged connection would it be used in?

IPS07

Home

PF0828-K2 You are installing components on a petrochemical build, what onsite reference should be used to position the component in the correct location? PF0802-K2 The drop in pipe level by introducing a Rise is otherwise know as what? PF0814-K3 The image shows a damaged O seal, what is the most likely cause of the damage? PF0806-K4 In which document would you find information about how to install pipe components in a system?

IPS08

Home

PF1059-K1 The maximum allowable operating pressure (MAOP) of a vessel list limited by what? PF1057-K3 A two meter length of steel pipe needs to be secured for hydrostatic testing, how should it be positioned?

IPS10

Home

PF1127-K7 Which of the following is a form of FME? PF1130-K3 Why is it important to provide engineered supports to components during dismantling operations? PF1126-K4 Which of the following is breaking containment? PF1112-K9 Which document authorises the removal of old pipework?

IPS11

Home