Lab practice #1

Materials

GreenHouse effect

  • Vernier® interface
  • Vernier® temperature probe
  • 250 or 500 mL beaker
  • Forceps
  • Plastic wash bottle
  • 100 mL graduated cylinder
  • Lamp with 100 watt bulb
  • Balance
  • Dry ice
  • Distilled water
  • Universal pH´s indicator

Per team bring...

  • Laptop with Logger Pro installed.
  • Masking Tape
  • Marker (sharpie)
  • Soil

Problem

Sequence of the practice

  • What is the relation between the temperature rise and the amount of carbon dioxide?
  • Calculate the "Temperature change/mass" ratio with the formula

Data processing

Data collection

Conclusions

Experiment 1

Experiment 2

2.1

2.2

Read the practice

Experiment 2.2

  • Repeat the process in the second beaker.
  • Add 1 cm of soil.
  • Weight less than a gram of dry ice and place it into the beaker and close it TIGHTLY with the plastic wrap.
  • Allow the dry ice to sublimate, you can help it by moving the beaker with the soil. DO NOT let the gas to escape!!
  • Place the lamp about 3-5 cm from the beaker.
  • Turn the lamp on and start the recording in Logger Pro.
  • After 4 min, turn the lamp off and keep recording for 3 more min.
  • Stop the recording and save the graph.

Measure the height reached by the CO2 gas from the water surface.

Step 4

Add a piece of dry ice into the water. Observe the changes in the color of the water. Register your observations

Step 3

Step 2

Step 1

Add two drops of universal indicator to the water

Pour 75 ml of tap water in the crystalizer dish

Experiment 2.1

  • In a beaker, tape the tip of the Vernier probe to the ruler. The tip should be 3 cm from the border of the ruler
  • Connect the Vernier probe into the computer with Logger Pro and set up the measurment to 10 min.
  • Add 1 cm of soil into the beaker and close it TIGHTLY with the plastic wrap.
  • Place the lamp about 3-5 cm from the beaker.
  • Turn the lamp on and start the recording in Logger Pro.
  • After 4 min, turn the lamp off and keep recording for 3 more min.
  • Stop the recording and save the graph.